Feature
Description
Processors
Intel 2nd & 3rd Generation Core i3, i5, i7 Processors; select processors include Intel vPro Technology, Intel Pentium
Chipset
Intel Q77 Express
Memory
CMT, MT, SFF
1600-MHz non-ECC DDR3 SDRAM; (4) DIMM slots enabling up to 32GB
USDT
1600-MHz non-ECC DDR3 SDRAM; (2) SO-DIMM slots enabling up to 16GB
Internal storage
A full range of hard disk and solid state storage drives, including some with self-encrypting capabilities, in capacities to meet today’s requirements.
Removable storage
Optional optical disc drives and a media card reader supporting data storage and backup, multi-media and software installation.
Input devices
A full range of optional keyboards and mice, including models featuring an integrated SmartCard Reader.

Physical specifications

Convertible Minitower specifications

Specification
Description
Chassis (H x W x D)
44.8 x 17.8 x 44.5 cm (17.6 x 7.0 x 18.0 in)
Approximate weight
11.2 kg (24.5 lb)
Weight supported (maximum distributed load in desktop position)
35 kg (77 lb)
Drive bays
  • External: (3) 13.33 cm (5.25 in)
  • Internal: (3) 8.89 cm (3.5 in)
Expansion slots
(3) PCI; (1) PCIe x1; (1) PCIe x4; (1) PCIe x16
Temperature range1
Operating
10° to 35°C (50° to 95°F)
Non-operating
-30° to 60°C (-22° to 140°F)
Relative humidity (noncondensing)
Operating
10-90%
Non-operating (38.7°C (101.66°F) max wet bulb)
5-95%
Maximum altitude (unpressurized)
Operating
30,4800 cm (10,000 ft)
Non-operating
91,4400 cm (30,000 ft)
Power supply2
Operating voltage range
90-264 V ac
Rated voltage range
100-240 V ac
Rated line frequency
50-60 Hz
Operating line frequency
47-63 Hz
Standard efficiency
320 W
High efficiency
320-W active PFC; 87/90/87% efficient at 20/50/100 % load
Rated input current
5.5 A
NOTE: 
1: Operating temperature is derated 1.0°C (50°F) per 30,000 cm (1000 ft) to 3,00,000 cm (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10°C/hr (50°F/hr). The upper limit may be limited by the type and number of options installed.
 
2: This system utilizes an active power factor corrected power supply. This allows the system to pass the CE mark requirements for use in the countries of the European Union. The active power factor corrected power supply also has the added benefit of not requiring an input voltage range select switch.

Microtower specifications

Specification
Description
Chassis (H x W x D)
37.7 x 17.7 x 43.1 cm (14.9 x 7.0 x 17.0 in)
Approximate weight
9.3 kg (20.5 lb)
Weight supported (maximum distributed load in desktop position)
35 kg (77 lb)
Drive bays
  • External: (2) 13.33 cm (5.25 in); (1) 8.89 cm (3.5 in)
  • Internal: (2) 8.89 cm (3.5 in)
Expansion slots
(1) PCI; (1) PCIe x1; (1) PCIe x4; (1) PCIe x16
Temperature range1
Operating
10° to 35°C (50° to 95°F)
Non-operating
-30° to 60°C (-22° to 140°F)
Relative humidity (noncondensing)
Operating
10-90%
Non-operating (38.7°C (101.66°F) max wet bulb)
5-95%
Maximum altitude (unpressurized)
Operating
30,4800 cm (10,000 ft)
Non-operating
91,4400 cm (30,000 ft)
Power supply2
Operating voltage range
90-264 V ac
Rated voltage range
100-240 V ac
Rated line frequency
50-60 Hz
Operating line frequency
47-63 Hz
Standard efficiency
320 W
High efficiency
320-W active PFC; 87/90/87% efficient at 20/50/100% load
Rated input current
5.5 A
NOTE: 
1: Operating temperature is derated 1.0°C (50°F) per 300 m (1000 ft) to 304800 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10°C/hr (50°F/hr). The upper limit may be limited by the type and number of options installed.
 
2: This system utilizes an active power factor corrected power supply. This allows the system to pass the CE mark requirements for use in the countries of the European Union. The active power factor corrected power supply also has the added benefit of not requiring an input voltage range select switch.